Dimension Charts
Tuyau de branchement d'eau en cuivre (recuit ou écroui) préisolé Urecon type K
Dimensions 13 mm (½ in) to 75 mm (3 in)
Diamètre nominal du tuyau | Diamètre extérieur du tuyau | Diamètre extérieur de l’isolant | Tuyau de branchement d’eau en cuivre type K | ||||||||
Épaisseur de l’isolant | Diamètre intérieur moyen du tuyau | Épaisseur minimale | Poids total | ||||||||
mm | po. | mm | po. | 50 mm | 2 po. | mm | po. | mm | po. | kg/m | lbs/pi |
13 | 0.5 |
16 | 0.625 | 133 |
5.25 | 13.4 | 0.527 | 1.24 | 0.049 | 1.95 | 1.31 |
19 | 0.75 | 22 | 0.875 | 133 | 5.25 | 18.9 | 0.745 | 1.65 | 0.065 | 2.38 | 1.60 |
25 | 1 | 29 | 1.125 | 133 | 5.25 | 25.3 | 0.995 | 1.65 | 0.065 | 2.66 | 1.79 |
38 | 1.5 | 41 | 1.625 | 156 | 6.13 | 37.6 | 1.481 | 1.83 | 0.072 | 3.77 | 2.53 |
50 | 2 | 54 | 2.125 | 165 | 6.50 | 49.8 | 1.959 | 2.11 | 0.083 | 5.03 | 3.38 |
64 | 2.5 | 67 | 2.625 | 181 | 7.13 | 61.8 | 2.435 | 2.41 | 0.095 | 6.49 | 4.37 |
75 | 3 | 79 | 3.125 | 197 | 7.75 | 73.8 | 2.907 | 2.77 | 0.109 | 7.76 | 5.22 |
- Épaisseur d'isolant pour protection contre le gel; 50 mm (2 po.); autres épaisseurs offertes sur demande.
- Épaisseur de gaine 1,27 mm (50 mils), polyéthylène; autres types et épaisseurs offerts sur demande.
- Tuyau isolé offert en longueurs de 3,66 m (12 pi.), 6,7 m (22 pi.) ou 10 m (33 pi.).
- Longueur non isolée de 150 mm (6 po.) jusqu’à 37 mm (1,5 po.) en diamètre et 225 mm (9 po.) pour 50 mm (2 po.) en diamètre et plus.
- Chaque longueur de tuyau est expédiée avec une trousse d'isolant pour joint de raccordement (sauf indications contraires).
- Normes de référence (tuyau): ASTM B88, CSA HC-76.
Tuyau de branchement d'eau cts en pehd préisolé urecon dr 11 (classe 160)
Diamètres Iron Pipe Size (IPS) 19 mm à 50 mm (0.75 po. à 2 po.)
Diamètre nominal du tuyau | Diamètre extérieur du tuyau | Insulation O.D. | HDPE DR 11, 1103 kPa (160 psi) IPS DIMENSION | ||||||||
Insulation Thickness | Average Pipe I.D. | Min. Wall Thickness | Total Weight | ||||||||
mm | in | mm | in | 50 mm | 2 in | mm | in | mm | in | kg/m | lbs/ft |
19 | 0.75 |
27 | 1.060 | 133 | 5.25 | 20.8 | 0.82 | 3.05 | 0.12 | 1.03 | 0.70 |
25 | 1 | 34 | 1.349 | 133 | 5.25 | 26.7 | 1.05 | 3.81 | 0.15 | 1.13 | 0.76 |
32 | 1.25 | 45 | 1.774 | 133 | 5.25 | 35.1 | 1.38 | 5.08 | 0.20 | 1.26 | 0.85 |
40 | 1.5 | 52 | 2.070 | 155 | 6.13 | 40.9 | 1.61 | 5.84 | 0.23 | 1.46 | 0.98 |
50 | 2 | 67 | 2.657 | 165 | 6.50 | 52.6 | 2.07 | 7.62 | 0.30 | 1.74 | 1.17 |
- Insulation thickness for freeze protection: 50 mm (2 in); other thicknesses available on request.
- Jacketing: 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
- Pressure rating of DR 11 HDPE is 1103 kPa (160 psi) at 23°C (73.4°F).
- Insulated pipe available in standard lengths of 12.19 m (40 ft); other lengths available on request.
- Insulation cut back: 150 mm (6 in), unless otherwise specified.
- Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
- Data may vary slightly from one pipe manufacturer to another.
- Stainless steel inserts must be used with IPS compression couplings and adapters.
- Reference specifications (core pipe), CSA B137.1
Urecon Pre-Insulated DR 11 (Series 160) HDPE CTS Water Service Pipe
Dimensions Copper Tube Size (CTS) 19 mm (¾ in) to 50 mm (2 in)
Nominal Pipe Size |
Outside |
Insulation O.D. | HDPE DR 11, 1103 kPa (160 psi) CTS DIMENSION | ||||||||
Insulation Thickness | Average Pipe I.D. | Min. Wall Thickness | Total Weight | ||||||||
mm | in | mm | in | 50 mm | 2 in | mm | in | mm | in | kg/m | lbs/ft |
19 | 0.75 |
22 | 0.875 | 133 | 5.25 |
17.0 | 0.67 | 2.46 | 0.09 | 1.03 | 0.70 |
25 | 1 | 28 | 1.125 | 133 | 5.25 | 21.9 | 0.86 | 3.15 | 0.12 | 1.13 | 0.76 |
32 | 1.25 | 35 | 1.375 | 133 | 5.25 | 26.8 | 1.05 | 3.88 | 0.15 | 1.26 | 0.85 |
40 | 1.5 | 41 | 1.625 | 155 | 6.13 | 31.6 | 1.24 | 4.60 | 0.18 | 1.46 | 0.98 |
50 | 2 | 54 | 2.125 | 165 | 6.50 | 41.4 | 1.63 | 5.97 | 0.23 | 1.74 | 1.17 |
- Insulation thickness for freeze protection: 50 mm (2 in); other thicknesses available on request.
- Jacketing: 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
- Pressure rating of DR 11 HDPE is 1103 kPa (160 psi) at 23°C (73.4°F).
- Insulated pipe available in standard lengths of 12.19 m (40 ft); other lengths available on request.
- Insulation cut back: 150 mm (6 in), unless otherwise specified.
- Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
- Data may vary slightly from one pipe manufacturer to another.
- Stainless steel inserts must be used with IPS compression couplings and adapters.
- Reference specifications (core pipe), CSA B137.1
Urecon Pre-Insulated DR 17 (Series 100) HDPE Duct
Dimensions 40 mm (1½ in) to 150 mm (6 in)
Nominal Pipe Size |
Outside |
Insulation O.D. | HDPE DUCT DR 17 (SERIES 100) | ||||||||
Insulation Thickness | Average Pipe I.D. | Min. Wall Thickness | Total Weight | ||||||||
mm | in | mm | in | 50 mm | 2 in | mm | in | mm | in | kg/m | lbs/ft |
40 | 1.5 | 48 | 1.90 | 155 | 6.13 | 42.16 | 1.66 | 2.79 | 0.11 | 1.10 | 0.74 |
50 | 2 | 60 | 2.38 | 165 | 6.50 | 52.83 | 2.08 | 3.55 | 0.14 | 1.34 | 0.90 |
75 | 3 | 88 | 3.50 | 196 | 7.75 | 77.72 | 3.06 | 5.33 | 0.21 | 2.35 | 1.58 |
100 | 4 | 114 | 4.50 | 228 | 9.00 | 100.07 | 3.94 | 6.86 | 0.27 | 3.53 |
2.37 |
150 | 6 | 168 | 6.63 | 279 | 11.00 | 147.32 | 5.80 | 9.91 | 0.39 | 6.52 | 4.38 |
- Insulation thickness for freeze protection: 50 mm (2 in); other thicknesses available on request.
- Jacketing: 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
- Pressure rating of DR 17 HDPE duct is 690 kPa (100 psi) at 23°C (73.4°F).
- Insulated duct available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft); other lengths available on request.
- Insulation cut back: Consult your Urecon representative for your application requirements.
- Each duct length shipped with suitable insulation kit for butt fused or heat shrink tube joint.
- Reference specifications (core pipe): ASTM D3035, CSA B137.1
Urecon Pre-Insulated SDR 26 (Series 160) PVC DUCT
Dimensions 40 mm (1½ in) to 150 mm (6 in)
Nominal Pipe Size |
Outside |
Insulation O.D. | PVC DUCT SDR 26 (SERIES 160) | ||||||||
Insulation Thickness | Average Pipe I.D. | Min. Wall Thickness | Total Weight | ||||||||
mm | in | mm | in | 50 mm | 2 in | mm | in | mm | in | kg/m | lbs/ft |
40 | 1.5 | 48 | 1.90 | 155 | 6.13 | 44 | 1.74 | 2.03 | 0.080 | 1.98 | 1.33 |
50 | 2 | 60 | 2.38 | 165 | 6.50 | 56 | 2.19 | 2.31 | 0.091 | 2.17 | 1.46 |
75 | 3 | 88 | 3.50 | 196 | 7.75 | 82 | 3.22 | 3.43 | 0.135 | 3.23 | 2.17 |
100 | 4 | 114 | 4.50 | 228 | 9.00 | 105 | 4.13 | 4.39 | 0.173 | 4.54 | 3.05 |
150 | 6 | 168 | 6.63 | 279 | 11.00 | 155 | 6.09 | 6.48 | 0.255 | 7.85 | 5.28 |
- Insulation thickness for freeze protection: 50 mm (2 in); other thicknesses available on request.
- Jacketing: 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
- Pressure rating of DR 26 PVC duct is 1103 kPa (160 psi) at 23°C (73.4°F).
- Insulated duct available in standard industry lengths of 6.1 m (20 ft).
- Insulation flush with bell end, cut back to insert depth on spigot end.
- Each duct length shipped with sufficient heat shrink wrap or H.D.P.E. tape to seal the insulation joint seam.
- Reference specifications (core pipe): ASTM D2241, CSA B137.3
Urecon Pre-Insulated PVC Sewer Pipe DR 35
Dimensions 100 mm (4 in) to 150 mm (6 in)
Nominal Pipe Size |
Outside |
Insulation O.D. | DR 35 | ||||||||
Insulation Thickness | Average Pipe I.D. | Min. Wall Thickness | Total Weight | ||||||||
mm | in | mm | in | 50 mm | 2 in | mm | in | mm | in | kg/m | lbs/ft |
100 | 4 | 107 | 4.22 | 229 | 9.00 | 100 | 3.97 | 3.06 | 0.125 | 3.84 | 2.58 |
135 | 5 | 143 | 5.64 | 248 | 9.75 | 135 | 5.31 | 4.10 | 0.161 | 4.83 | 3.49 |
150 | 6 | 160 | 6.28 | 279 | 11.00 | 150 | 5.92 | 4.57 | 0.180 | 6.28 | 4.22 |
- Insulation thickness for freeze protection: 50 mm (2 in) minimum; other thicknesses available on request.
- Jacketing: 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
- Standard industry lengths of 4 m (13 ft).
- Data and size availability may vary from one manufacturer to another.
- Insulation flush with bell end, cut-back to insertion depth on spigot end.
- Each duct length is shipped with sufficient heat shrink wrap on HDPE tape to seal the insulation joint seam.
- Reference specifications (core pipe): ASTM D3034, CSA B182.2., NQ3624-130 and NQ3624-135.
Urecon Pre-Insulated PVC Sewer Pipe DR 28
Dimensions 100 mm (4 in) to 150 mm (6 in)
Nominal Pipe Size |
Outside |
Insulation O.D. | DR 28 | ||||||||
Insulation Thickness | Average Pipe I.D. | Min. Wall Thickness | Total Weight | ||||||||
mm | in | mm | in | 50 mm | 2 in | mm | in | mm | in | kg/m | lbs/ft |
100 | 4 | 107 | 4.22 | 229 | 9.00 | 99 | 3.91 | 3.81 | 0.150 | 4.13 | 2.78 |
135 | 5 | 143 | 5.64 | 248 | 9.75 | 133 | 5.24 | 5.11 | 0.201 | 6.20 | 4.17 |
150 | 6 | 160 | 6.28 | 279 | 11.00 | 148 | 5.83 | 5.69 | 0.224 | 7.05 | 4.74 |
- Insulation thickness for freeze protection: 50 mm (2 in) minimum; other thicknesses available on request.
- Jacketing: 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
- Standard industry lengths of 4 m (13 ft).
- Data and size availability may vary from one manufacturer to another.
- Insulation flush with bell end, cut-back to insertion depth on spigot end.
- Each duct length is shipped with sufficient heat shrink wrap on HDPE tape to seal the insulation joint seam.
- Reference specifications (core pipe): ASTM D3034, NQ3624-130 and CSA B182,2.
Urecon Pre-Insulated HDPE Core Sewer Pipe DR 26
Dimensions 75 mm (3 in) to 300 mm (12 in)
Nominal Pipe Size |
Outside |
Insulation O.D. | DR 26, 441 kPa (64 psi) | ||||||||
Insulation Thickness | Average Pipe I.D. | Min. Wall Thickness | Total Weight | ||||||||
mm | in | mm | in | 50 mm | 2 in | mm | in | mm | in | kg/m | lbs/ft |
75 | 3 | 88 | 3.50 | 196 | 7.75 | 81.50 | 3.21 | 3.56 | 0.14 | 1.89 | 1.27 |
100 | 4 | 114 | 4.50 | 228 | 9.00 | 104.90 | 4.13 | 4.32 | 0.17 | 2.77 | 1.86 |
150 | 6 | 168 | 6.625 | 279 | 11.00 | 154.43 | 6.08 | 6.60 | 0.26 | 4.88 | 3.28 |
200 | 8 | 219 | 8.625 | 336 | 13.25 | 201.17 | 7.92 | 8.38 | 0.33 | 7.68 | 5.16 |
250 | 10 | 273 | 10.75 | 393 | 15.50 | 250.70 | 9.87 | 10.41 | 0.41 | 11.27 | 7.57 |
300 | 12 | 324 | 12.75 | 438 | 17.50 | 297.43 | 11.71 | 12.45 | 0.49 | 15.21 | 10.22 |
- Insulation thickness for freeze protection: 50 mm (2 in) minimum; other thicknesses available on request.
- Jacketing: 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
- Pressure rating of DR 26 is 441 kPa (64 psi) at 23°C (73.4°F).
- Insulated pipe available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft);
other lengths available on request. - Insulation cut back: standard 230 mm (9 in); Consult your Urecon representative for your application requirements.
- Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
- Data may vary slightly from one pipe manufacturer to another.
- Reference specifications (core pipe): see HDPE pipe specifications.